# Troubleshooting & USB Flashing Diagnostics
|
||||
|
||||
This document covers common issues when flashing OpenKE via USB OTA, root causes, and diagnostic steps.
|
||||
|
||||
---
|
||||
|
||||
## 1. "No firmware found" / "No local update available"
|
||||
|
||||
When you insert the USB drive and navigate to **Settings** $\rightarrow$ **Firmware Update** $\rightarrow$ **Local Update**, the screen reports no file found.
|
||||
|
||||
### Root Causes & Fixes:
|
||||
1. **USB Drive File System**:
|
||||
* The Creality Linux kernel does not reliably mount exFAT or NTFS drives on early boot.
|
||||
* **Fix**: Format the USB flash drive as **FAT32** with an **MBR** (Master Boot Record) partition table. Avoid GPT partition tables on the flash drive.
|
||||
2. **File Location**:
|
||||
* The `.img` file must be placed in the **root directory** of the USB drive (e.g. `E:\NEBULA_ota_img_V1.1.0.34.img`), not inside a folder.
|
||||
3. **Filename Format**:
|
||||
* Creality's `master-server` scans for files matching `ota_img_V`.
|
||||
* Files must be named:
|
||||
- For Nebula Pad: `NEBULA_ota_img_V<version>.img`
|
||||
- For Ender-3 V3 KE: `Ender-3_V3_KE_F005_ota_img_V<version>.img`
|
||||
|
||||
---
|
||||
|
||||
## 2. "Update failed" Immediately After Confirming
|
||||
|
||||
The screen detects the update, you click "Update Now", the progress bar appears for a split second, and it immediately reports "Update Failed".
|
||||
|
||||
### Root Cause:
|
||||
* Creality's updater extracts the 7z archive to a temporary directory and looks for `ota_config.in` in `<TEMP_DIR>/<UNZIP_FOLDER>/ota_config.in`.
|
||||
* If the root directory inside the 7z archive does not match the `.img` filename (without `.img`), `cp -f $ota_site_config` fails.
|
||||
* **Resolution**: The updated `build_openke_image.sh` / `tools/pack_openke.py` guarantees this alignment automatically. Ensure you use images built with the latest packager.
|
||||
|
||||
---
|
||||
|
||||
## 3. "Current version is newest" / Won't Allow Flashing
|
||||
|
||||
The UI says the firmware is already up-to-date or newer.
|
||||
|
||||
### Root Cause:
|
||||
* In `local_ota_update.sh`:
|
||||
```bash
|
||||
if [ $current_version -ge $ota_current_version ]; then
|
||||
echo "ota not update: current version is newest"
|
||||
exit 2
|
||||
fi
|
||||
```
|
||||
* If your device is running `1.1.0.30` and the package version is `1.1.0.30` or lower, it refuses to flash.
|
||||
* **Fix**: Pass a higher version number when running the build script:
|
||||
```bash
|
||||
./build_openke_image.sh --target nebula --version 1.1.0.35
|
||||
```
|
||||
|
||||
---
|
||||
|
||||
## 4. How to Inspect Live Update Logs on the Printer
|
||||
|
||||
If you have SSH access to stock firmware and want to see what `local_ota_update.sh` is doing during a flash:
|
||||
|
||||
1. Connect to the printer via SSH:
|
||||
```bash
|
||||
ssh root@<printer-ip>
|
||||
```
|
||||
2. Trigger the local update manually from the command line to see stdout/stderr in real time:
|
||||
```bash
|
||||
sh -x /etc/ota_bin/local_ota_update.sh /media/sda1/NEBULA_ota_img_V1.1.0.34.img
|
||||
```
|
||||
3. Check temporary updater logs:
|
||||
```bash
|
||||
ls -la /usr/data/creality/ota_updater*
|
||||
```
|
||||