2.8 KiB
2.8 KiB
Troubleshooting & USB Flashing Diagnostics
This document covers common issues when flashing OpenKE via USB OTA, root causes, and diagnostic steps.
1. "No firmware found" / "No local update available"
When you insert the USB drive and navigate to Settings \rightarrow Firmware Update \rightarrow Local Update, the screen reports no file found.
Root Causes & Fixes:
- USB Drive File System:
- The Creality Linux kernel does not reliably mount exFAT or NTFS drives on early boot.
- Fix: Format the USB flash drive as FAT32 with an MBR (Master Boot Record) partition table. Avoid GPT partition tables on the flash drive.
- File Location:
- The
.imgfile must be placed in the root directory of the USB drive (e.g.E:\NEBULA_ota_img_V1.1.0.34.img), not inside a folder.
- The
- Filename Format:
- Creality's
master-serverscans for files matchingota_img_V. - Files must be named:
- For Nebula Pad:
NEBULA_ota_img_V<version>.img - For Ender-3 V3 KE:
Ender-3_V3_KE_F005_ota_img_V<version>.img
- For Nebula Pad:
- Creality's
2. "Update failed" Immediately After Confirming
The screen detects the update, you click "Update Now", the progress bar appears for a split second, and it immediately reports "Update Failed".
Root Cause:
- Creality's updater extracts the 7z archive to a temporary directory and looks for
ota_config.inin<TEMP_DIR>/<UNZIP_FOLDER>/ota_config.in. - If the root directory inside the 7z archive does not match the
.imgfilename (without.img),cp -f $ota_site_configfails. - Resolution: The updated
build_openke_image.sh/tools/pack_openke.pyguarantees this alignment automatically. Ensure you use images built with the latest packager.
3. "Current version is newest" / Won't Allow Flashing
The UI says the firmware is already up-to-date or newer.
Root Cause:
- In
local_ota_update.sh:if [ $current_version -ge $ota_current_version ]; then echo "ota not update: current version is newest" exit 2 fi - If your device is running
1.1.0.30and the package version is1.1.0.30or lower, it refuses to flash. - Fix: Pass a higher version number when running the build script:
./build_openke_image.sh --target nebula --version 1.1.0.35
4. How to Inspect Live Update Logs on the Printer
If you have SSH access to stock firmware and want to see what local_ota_update.sh is doing during a flash:
- Connect to the printer via SSH:
ssh root@<printer-ip> - Trigger the local update manually from the command line to see stdout/stderr in real time:
sh -x /etc/ota_bin/local_ota_update.sh /media/sda1/NEBULA_ota_img_V1.1.0.34.img - Check temporary updater logs:
ls -la /usr/data/creality/ota_updater*